Peter Paul Solenoid Valve Model H22

Contact us to get your personalized offer

PeterPaul single orifice valves feature an orifice that is closed in the de-energized position, preventing any flow between the inlet and outlet ports. When the valve coil is energized, the plunger is drawn towards the sleeve end stop, accelerating freely for a short distance before making contact with the shoulder of the sealing pin. This contact imparts considerable force on the pin, causing it to lift the seat. A return spring provides the necessary force to seal the orifice when the coil is de-energized. The valve must be mounted within 30 degrees of vertical and is suitable for use with air, other non-corrosive gases, water, and oil.

  • Kel-F pin sealing element.
  • Orifice guides the sealing pin for perfect alignment.
  • Simple construction…only two moving parts.

Available on backorder

Description

GAS PRESSURE
RATINGS
ORIFICE SIZECV FACTORVALVE NUMBER
ACDCGROMMET HOUSINGCONDUIT HOUSING
1/8″ NPT PORTS1/4″ NPT PORTS1/8″ NPT PORTS1/4″ NPT PORTS
5000*5000*.025.010H22M7DGMH22M9DGMH22M7DCMH22M9DCM
3000*3000*1/32.022H22G7DGM H22G9DGMH22G7DCMH22G9DCM
2500*1500*3/64.041H22H7DGMGH22H9DGMGH22H7DCMGH22H9DCMG
1750*5001/16.065H22J7DGMGH22J9DGMGH22J7DCMGH22J9DCMG
650*1003/32.100H22K7DGMGH22K9DGMGH22K7DCMGH22K9DCMG

 

LIQUID PRESSURE
RATINGS
ORIFICE SIZECV FACTORVALVE NUMBER
ACDCGROMMET HOUSINGCONDUIT HOUSING
1/8″ NPT PORTS1/4″ NPT PORTS1/8″ NPT PORTS1/4″ NPT PORTS
5000*5000*.025.010H22M7DGMH22M9DGMH22M7DCMH22M9DCM
3000*3000*1/32.022H22G7DGMH22G9DGMH22G7DCMH22G9DCM
1500*1500*3/64.041H22H7DGMLH22H9DGMLH22H7DCMLH22H9DCML
1000*5001/16.065H22J7DGMLH22J9DGMLH22J7DCMLH22J9DCML
3001003/32.100H22K7DGMLH22K9DGMLH22K7DCMLH22K9DCML

* FKM seals not recommended for pressure above 500 psi.

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (H22J7DGMG 120/60) repair pack (KH22JD AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OH22JDDGMG 120/60)

 

Operating Conditions:

  • Media: Air and other non-corrosive gasses, water and oil.
  • Valve Temperature Range:
    • Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
    • Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 10,000 PSI
  • Leakage: Bubbletight (with polymer sealing pins)

 

Electrical Characteristics:

  • Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
  • Nominal Power: AC — 7.7 Watts DC — 9.5 Watts
  • Coil Construction: Molded (Std.), Non-molded Class A and Potted Class F or Class H (Opt.)
  • Typical Response Time on Air:  4 – 16 Milliseconds
  • Operating Speed:  Up to 600 CPM
  • Duty Cycle:  Continuous

 

Mechanical Characteristics

  • Body: Stainless Steel
  • Internal Components: Stainless Steel. Copper – AC Only.
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Sealing Pin: Kel-F (Std.)
  • Orifice Diameter: See table above.
  • Porting: 1/8″ and 1/4″ NPT (other ports avaialble).
  • Housing: Grommet and 1/2″ NPT conduit – many options available.*
  • Mounting: Must be mounted within 30° of vertical.
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: Grommet Valve: 1.13 lbs, Conduit Valve: 1.19 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Alternate Elastomers, Alternate Sealing Pin Materials, Spade Terminal Coil, and European Style DIN Coil*

* Consult us for options and specifications

Additional information

Weight1.5 kg
Type

Orifice/Port Size

1/4" NPT

Pressure

0 – 5000 PSI

Flow

.010 – .100 CV