Peter Paul Magnetic Latching Valve Model MLV 23 [Exhaust to atmosphere]

Contact us to get your personalized offer

PeterPaul dual orifice valves are configured with the body orifice closed and the sleeve orifice open in the de-energized position. This design ensures that no flow can occur between the inlet and cylinder ports, while allowing flow between the cylinder and exhaust ports. Specifically, the 3-Way Normally Closed Magnet Latching Valve — Exhaust to Atmosphere variant is particularly suitable for applications in remote areas with limited or intermittent power availability, or in battery-powered portable equipment where power conservation is crucial. It is also beneficial in systems where continuous coil heating is undesirable. These valves are compatible with air and other fluids that can use standard Buna seals. For applications involving hot water, steam, gasoline, oils, some hydraulic fluids, and other demanding media, special seal materials may be required to ensure optimal performance and longevity.

  • Valve is magnetic latching.
  • Meets today’s demand for economy of space.
  • Uses power only during latching and un-latching.
  • Great for medical and chemical analyzers.

Available on backorder

Description

MAX OPER
PRESS. DIFF
ORIFICE SIZECV FACTORVALVE NUMBER
DCINLETEXHINLETEXHDIN COILLEADED COIL
1/8″ NPT PORTS1/4″ NPT PORTS1/8″ NPT PORTS1/4″ NPT PORTS
4001/321/32.024.02423GG7DELM23GG9DELM23GG7DGLM23GG9DGLM
1503/641/16.052.09523HJ7DELM23HJ9DELM23HJ7DGLM23HJ9DGLM
1001/161/16.095.09523JJ7DELM23JJ9DELM23JJ7DGLM23JJ9DGLM
1001/163/32.095.15623JK7DELM23JK9DELM23JK7DGLM23JK9DGLM
753/323/32.156.15623KK7DELM23KK9DELM23KK7DGLM23KK9DGLM
501/83/32.214.15623NK7DELM23NK9DELM23NK7DGLM23NK9DGLM
203/163/32.500.15623PK7DELM23PK9DELM23PK7DGLM23PK9DGLM

 

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (23JJ7DELM 12/DC) repair pack (K23JJDL DC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O23JJDDELM 12/DC)

 

Operating Conditions:

  • Media: Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
  • Valve Temperature Range:
    • Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
    • Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 5,000 PSI
  • Leakage: Bubbletight (with polymer sealing pins)
  • Vacuum:  To 5 Microns*

 

Electrical Characteristics:

  • Coil Voltage: 12, 24/DC
  • Nominal Power: DC — 10.0 Watts
  • Coil Construction: Molded Class B with DIN 43650 Form A Connector (Std.), Leadwires (Opt.) For your convenience we have the female DIN style mating connector No. 20-198** available for an additional fee.*
  • Typical Response Time on Air: Approximate 50 millisecond pulse to energize and de-energize.
  • Operating Speed:  Up to 600 CPM

 

Mechanical Characteristics

  • Body: Stainless Steel (Std.) or Brass (Opt.)
  • Internal Components: Stainless Steel
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Orifice Diameter: See table above
  • Porting: Standard 1/8” and 1/4” NPT (other ports available).*
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: 1.2 lb average
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering and Alternate Elastomers*

* Consult us for options and specifications

Additional information

Weight1.5 kg
Type

Orifice/Port Size

1/8" or 1/4" NPT

Pressure

0 – 400 PSI

Flow

.024 – .700 CV