Peter Paul Hazardous Location Valve with Piped Exhaust Model LLW53

General purpose valve for pneumatic applications. The versatility of these valves is increased to include the handling of hot air, refrigerants and many other media, by the use of different seals. Air and other gases compatible with standard Buna seals. • General purpose valve with reduced power consumption. • Increased versatility. • For pneumatic application. • Increased to handle hot air, and other gases. • High quality engineering.

Available on backorder

MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORVALVE NUMBER
GAS
DCN.C.N.O.N.C.N.O.GROMMET 1/8" NPTCONDUIT 1/8" NPT
1201/321/32.022.022LLW53G8XGMLLW53G8XCM

 
Operating Conditions:

  • Media:Air and other gases only compatible with standard Buna seals.*
  • Valve Temperature Range: Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 5000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics: 

  • Coil Voltage: 12, 24/DC
  • Nominal Power: DC — 0.65 Watts
  • Coil Construction: Non-molded Class A, Molded and potted Class F. (Class H optional)
  • Typical Response Time on Air: 4 – 16 Milliseconds
  • Operating Speed: Up to 600 CPM
  • Duty Cycle: Continuous

 

Mechanical Characteristics: 

  • Body: Stainless Steel (Std.), Brass (Opt.) or Aluminum (Opt.)
  • Internal Components: Stainless Steel
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Orifice Diameter: See table above.
  • Porting: 1/8″ NPT (Std.)
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: Grommet Valve: 0.38 lbs, Conduit Valve: 0.44 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering and Alternate Elastomers*
Weight1.5 kg
Pressure

5000 PSI

Flow

.022 – .156 CV

Wattage

2.5kW

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G