Peter Paul Hazardous Location Valve with Piped Exhaust Model ELW53

A UL and CSA listed, low watt, miniature hazardous location valve with minimal space and energy requirements in volatile environments. Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials. • Smallest hazardous location solenoid valve. • Best ambient and high temperature ratings on the market. • NEMA 4 rating is standard with encapsulated coil. • High quality engineering.

Available on backorder

MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORVALVE NUMBER
GASLIQUID
ACDCACDCN.C.N.O.N.C.N.O.
2151352151351/321/32.022.020ELW53GG8XCCP
215120120651/323/64.022.048ELW53GH8XCCP
1355040301/321/16.022.075ELW53GJ8XCCP
703530201/321/16.022.134ELW53GV8XCCP
553025151/323/32.022.150ELW53GK8XCCP
12070120653/643/64.055.048ELW53HH8XCCP
1205040303/641/16.055.075ELW53HJ8XCCP
703530203/641/16.055.134ELW53HV8XCCP
553025153/643/32.055.150ELW53HK8xCCP
854040301/161/16.075.075ELW53JJ8xCCP
703530201/161/16.075.134ELW53JV8XCCP
553025151/163/32.075.150ELW53JK8XCCP
503030205/641/16.134.134ELW53VV8XCCP
503025155/643/32.134.150ELW53VK8XCCP
352025155/643/32.156.150ELW53KK8XCCP

 

Operating Conditions:

  • Media:Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
  • Valve Temperature Range:Standard Valves – 0°F (-18°C) to 140°F (60°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 5000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics: 

  • Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
  • Nominal Power: AC — 1.8 Watts DC — 1.8 Watts
  • Coil Construction: Encapsulated Class F Coil with third wire ground
  • Typical Response Time on Air: 4 – 16 Milliseconds
  • Operating Speed: Up to 600 CPM
  • Duty Cycle: Continuous

 

Mechanical Characteristics: 

  • Body: Stainless Steel (Std.)
  • Internal Components:Stainless Steel. Copper – AC Only.
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Orifice Diameter: See table above.
  • Porting: 1/8″ NPT (Std.)
  • Housing: Encapsulated with 1/2 NPT conduit
  • Listings: Valves are UL listed for Hazardous Locations — Class I, Div 1, Groups A, B, C, and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G. “T” Rating as low as T5.
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: 0.60 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*
Weight1.5 kg
Pressure

5000 PSI

Flow

.022 – .156 CV

Wattage

1.8W

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G