Peter Paul Hazardous Location Valve with Piped Exhaust Model EL53

Low Wattage Hazardous Location 3-Way Normally Closed Valve (piped exhaust) PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.

  • Miniature Hazardous Location valves using even less power than an E53.
  • Flame-Proof construction.
  • High quality engineering.

Available on backorder

+ MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
ACDCINLETEXHINLETEXH
1201201/321/32.022.048EL53GG8XCCM-∆
1201201/323/64.055.048EL53GH8XCCM-∆
60603/643/64.055.048EL53HH8XCCM-∆
30301/161/16.075.075EL53JJ8XCCM-∆

 

Ordering Information:

Seal Material:  Replace ∆ with desired code  –  Blank = Nitrile (Buna)      S = Low Temp Buna.      N = FKM*      E = Neoprene    A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (EL53HH8XCCM 120/60) repair pack (5KEL53HHX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OEL53HHDDCCM 120/60)

 

Operating Conditions:

  • Media: Air and other common gases and common refrigerants except ammonia, city gas supplies by public utilities, Nos. 1 and 2 fuel oils, oils having viscosities not more than 40, SU at 100° F, steam, some hydraulic and water or other aqueous non-flammable liquid
  • Valve Temperature Range:
    • Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media
    • Optional Valves – can tolerate much higher or much lower ambient and media temperatures.
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 4,000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics:

  • Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
  • Nominal Power: AC — 1.8 Watts, DC — 1.8 Watts
  • Coil Construction: Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
  • Typical Response Time on Air: 4 – 16 Milliseconds
  • Operating Speed: Up to 600 CPM
  • Duty Cycle:  Continuous

 

Mechanical Characteristics

  • Body: Stainless Steel (Std.)
  • Internal Components: Stainless Steel. Copper – AC Only.
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Orifice Diameter: See table above.
  • Porting: 1/8″ NPT (Std.)
  • Housing: Flame-Proof construction with 1/2″ NPT conduit
  • Listings: Valves are UL listed for Hazardous Locations. — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2 Groups A, B, C, D, E, F, and G.
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight:0.65 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*

* Consult us for options and specifications

Weight1.5 kg
Orifice/Port Size

1/8" NPT

Pressure

0 – 120 PSI

Flow

.020 – .075 CV

Wattage

1.8W

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G