Peter Paul Hazardous Location Valve Model LW51
General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants and many other media, by the use of different seals. Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.
- General purpose valve with reduced power consumption.
- Increased versatility.
- For pneumatic and hydraulic application.
- Increased to handle hot air, water and refrigerants.
- High quality engineering.
Available on backorder
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER | ||||
|---|---|---|---|---|---|---|---|
| GAS | LIQUID | ||||||
| AC | DC | AC | DC | GROMMET 1/8" NPT | CONDUIT 1/8" NPT | ||
| 300 | 200 | 300 | 200 | 1/32 | .020 | LW51G8XGM | LW51G8XCM |
| 270 | 120 | 120 | 65 | 3/64 | .048 | LW51H8XGM | LW51H8XCM |
| 135 | 50 | 40 | 30 | 1/16 | .075 | LW51J8XGM | LW51J8XCM |
| 70 | 35 | 30 | 20 | 5/64 | .134 | LW51V8XGM | LW51V8XCM |
| 55 | 30 | 25 | 15 | 3/32 | .156 | LW51K8XGM | LW51K8XCM |
Ordering Information:
When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (LW51J8XGML 120/60) repair pack (KLW51JX AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OLW51JDDGML 120/60)
Electrical Characteristics:
- Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
- Nominal Power: AC — AC — 2.5 Watts DC — 2.5 Watts
- Coil Construction: Non-molded Class A, Molded and potted Class F. (Class H optional)
- Typical Response Time on Air: 4 – 16 Milliseconds
- Duty Cycle: Continuous
Mechanical Characteristics:
- Body: Stainless Steel (Std.), Brass (Opt.) or Aluminum (Opt.)
- Internal Components: Stainless Steel. Copper – AC Only.
- Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
- Orifice Diameter: See table above.
- Porting: 1/8″ NPT (Std.)
- Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
- Valve Weight: Grommet Valve: 0.38 lbs, Conduit Valve: 0.44 lbs
- Repair Packs: See table above.
| Weight | 1.5 kg |
|---|---|
| Orifice/Port Size | 1/8" NPT |
| Pressure | 5000 PSI |
| Flow | .020 – .156 CV |
| Wattage | 1.8W |
| SPECIAL NOTE | Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G |