Peter Paul Hazardous Location Valve Model LW51

General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants and many other media, by the use of different seals. Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.

  • General purpose valve with reduced power consumption.
  • Increased versatility.
  • For pneumatic and hydraulic application.
  • Increased to handle hot air, water and refrigerants.
  • High quality engineering.

Available on backorder

MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORVALVE NUMBER
GASLIQUID
ACDCACDCGROMMET 1/8" NPTCONDUIT 1/8" NPT
3002003002001/32.020LW51G8XGMLW51G8XCM
270120120653/64.048LW51H8XGMLW51H8XCM
1355040301/16.075LW51J8XGMLW51J8XCM
703530205/64.134LW51V8XGMLW51V8XCM
553025153/32.156LW51K8XGMLW51K8XCM

 

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (LW51J8XGML 120/60) repair pack (KLW51JX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OLW51JDDGML 120/60)

Operating Conditions:

  • Media: Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
  • Valve Temperature Range: Standard Valves – 0°F (-18°C) to 140°F (60°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures. *
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 5,000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics: 

  • Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
  • Nominal Power: AC — AC — 2.5 Watts DC — 2.5 Watts
  • Coil Construction: Non-molded Class A, Molded and potted Class F. (Class H optional)
  • Typical Response Time on Air: 4 – 16 Milliseconds
  • Operating Speed: Up to 600 CPM
  • Duty Cycle: Continuous

 

Mechanical Characteristics: 

  • Body: Stainless Steel (Std.), Brass (Opt.) or Aluminum (Opt.)
  • Internal Components: Stainless Steel. Copper – AC Only.
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Orifice Diameter: See table above.
  • Porting: 1/8″ NPT (Std.)
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: Grommet Valve: 0.38 lbs, Conduit Valve: 0.44 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering, Alternate Elastomers*
Weight1.5 kg
Orifice/Port Size

1/8" NPT

Pressure

5000 PSI

Flow

.020 – .156 CV

Wattage

1.8W

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G