Peter Paul Hazardous Location Valve Model EL52

Contact us to get your personalized offer

PeterPaul single orifice valves have an orifice that remains closed in the de-energized position, preventing any flow between the inlet and outlet ports. Additionally, PeterPaul explosion-proof valves are essential in environments with fire or explosion hazards due to the presence of flammable gases, vapors, liquids, combustible dust, or easily ignitable fibers. These hazardous location valves are recommended, and sometimes compulsory, where a high level of explosion protection is necessary.

  • Miniature Hazardous Location valve.
  • Flame-Proof construction.
  • High quality engineering.

Available on backorder

Description

MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
ACDC
1201201/32.022EL52G8DCCM-∆
80803/64.055EL52H8DCCM-∆
50501/16.075EL52J8DCCM-∆

Ordering Information:

Seal Material: Replace ∆ with desired code – Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (EL52H8DCCM 120/60) repair pack (5KEL52H AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OEL52HDDCCM 120/60)

 

Operating Conditions:

  • Media: Air and other common gases and common refrigerants except ammonia, city gas supplies by public utilities, Nos. 1 and 2 fuel oils, oils having viscosities not more than 40, SU at 100°F, steam, some hydraulic and water or other aqueous non-flammable liquids
  • Valve Temperature Range:
    • Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
    • Optional Valves – can tolerate much higher or much lower ambient and media temperatures.
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 4,000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics:

  • Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
  • Nominal Power: AC — 1.8 Watts DC — 1.8 Watts
  • Coil Construction: Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
  • Typical Response Time on Air: 4 – 16 Milliseconds
  • Operating Speed: Up to 600 CPM
  • Duty Cycle:  Continuous

 

Mechanical Characteristics

  • Body: Stainless Steel (Std.)
  • Internal Components: Stainless Steel
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Orifice Diameter: See table above.
  • Porting: 1/8″ NPT (Std.)
  • Housing: Flame-Proof construction with 1/2″ NPT conduit
  • Listings: Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups C, D, E, F, and G
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: 0.65 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*

Additional information

Weight1.5 kg
Type

Orifice/Port Size

1/8" NPT

Pressure

0 – 120 PSI

Flow

.020 – .075 CV

Wattage

1.8W

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G