Peter Paul Hazardous Location Valve Model EL24

Contact us to get your personalized offer

PeterPaul dual orifice valves feature a closed body orifice and an open sleeve orifice in the de-energized position, preventing flow between the exhaust and cylinder ports while allowing flow between the inlet and cylinder ports.

Additionally, PeterPaul explosion-proof valves are essential in environments with fire or explosion hazards caused by flammable gases, vapors, liquids, combustible dust, or easily ignitable fibers. These hazardous location valves are recommended, and sometimes compulsory, where a high level of explosion protection is required.

  • Explosion Proof
  • The flagship valve initially created for fluid power industry.
  • Heavy duty and made of stainless steel.
  • A real workhorse with proven performance.
  • It has the greatest amount of options available of all the valves.
  • Wide range of orifice sizes from 1/32″ to 1/8″.

Available on backorder

Description

MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBERVALVE NUMBER
DCINLETEXHINLETEXH1/8 NPT PORTS1/4 NPT PORTS
4001/321/32.024.024EL24GG7XCCP-∆EL24GG9ZCCP-∆
1503/643/64.052.052EL24HH7XCCP-∆EL24HH9ZCCP-∆
401/161/16.095.095EL24JJ7XCCP-∆EL24JJ9ZCCP-∆
253/323/32.156.156EL24KK7XCCP-∆EL24KK9ZCCP-∆

Ordering Information:

Seal Material:  Replace ∆ with desired code  –  Blank = Nitrile (Buna)      S = Low Temp Buna.      N = FKM*      E = Neoprene    A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (EL24GG7XCCP-N 24/DC) repair pack (2KEL24GG-N DC)

When ordering operators add the letter “O” to the front of the valve number, and the body code will change. Contact the factory for the complete part number.

 

Operating Conditions:

  • Media: Air, water, and other fluids compatible with standard Buna seals. Hot water, steam gasoline, and many oils require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
  • Valve Temperature Range: -22°F(-30°C) to 140°F (60°C) Exception: FKM is -4°F (-20°C) to 140°F (60°C).
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 5,000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics:

  • Coil Voltage: 12, 24/DC
  • Nominal Power: 1.8 Watts
  • Coil Construction: Potted Class F coil with 36” black lead wires and 36” green ground wire.
  • Typical Response Time on Air:  4 – 16 Milliseconds
  • Operating Speed:  Up to 600 CPM
  • Duty Cycle:  Continuous

 

Mechanical Characteristics

  • Body: Stainless Steel (Std.)
  • Internal Components: Stainless Steel. Copper – AC Only.
  • Elastomers: Buna, Fluorocarbon (FKM), Low Temperature Buna, EPDM or Neoprene.
  • Orifice Diameter: See table above.
  • Porting: 1/8” OR 1/4” NPT
  • Housing: Flame-Proof construction with 1/2″ NPT conduit
  • Listings: Valves are cULus listed for Hazardous Locations. — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2 Groups A, B, C, D, E, F, and G.
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: 1.38 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering, Manual Override, Alternate Elastomers*

* Consult us for options and specifications

Additional information

Weight1.5 kg
Type

Orifice/Port Size

1/8" or 1/4" NPT

Pressure

0 – 400 PSI

Flow

.024 – .156 CV

Wattage

1.8W

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G