Peter Paul Hazardous Location Valve Model EL22

Contact us to get your personalized offer

PeterPaul single orifice valves have an orifice that remains closed in the de-energized position, preventing any flow between the inlet and outlet ports. Additionally, PeterPaul explosion-proof solenoid valves are essential in environments with fire or explosion hazards due to the presence of flammable gases, vapors, liquids, combustible dust, or easily ignitable fibers. Their low watt feature ensures low power consumption, reducing the drain on electrical systems, making them especially beneficial for renewable energy applications and situations where the solenoid valve must remain continuously on.

• Heavy duty and made of stainless steel.
• A real workhorse with proven performance.
• Low power consumption best for renewable energy and limited
resource applications.
• Wide range of orifice sizes from 1/32′′ to 1/8′′.

Available on backorder

Description

MAX OPERATING
PRESS. DIFF.
ORIFICE SIZECV
FACTOR
VALVE NUMBER
DC1/8 NPT PORTS1/4 NPT PORTS
5001/32.024EL22G7DCCP-∆EL22G9DCCP-∆
2503/64.052EL22H7DCCP-∆EL22H9DCCP-∆
1251/16.095EL22J7DCCP-∆EL22J9DCCP-∆
753/32.156EL22K7DCCP-∆EL22K9DCCP-∆
501/8.284EL22N7DCCP-∆EL22N9DCCP-∆

Ordering Information:

Seal Material: Replace ∆ with desired code – Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (EL22N7DCCP-N 24/DC) repair pack (2KEL22N-N DC)

When ordering operators add the letter “O” to the front of the valve number, and the body code will change. Contact the factory for the complete part number.

Operating Conditions:

  • Media: Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
  • Valve Temperature Range: -22°F(-30°C) to 140°F (60°C) Exception: FKM is -4°F (-20°C) to 140°F (60°C).
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 5,000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics:

  • Coil Voltage: 12/DC, 24/DC.
  • Nominal Power: 1.8 Watts
  • Coil Construction: Potted Class F coil with 36” black lead wires and 36” green ground wire.
  • Typical Response Time on Air:  4 – 16 Milliseconds
  • Operating Speed:  Up to 600 CPM
  • Duty Cycle:  Continuous

 

Mechanical Characteristics

  • Body: Stainless Steel (Std.)
  • Internal Components: Stainless Steel
  • Elastomers: Buna, Fluorocarbon (FKM), Low Temperature Buna, EPDM or Neoprene.
  • Orifice Diameter: See table above.
  • Porting: 1/8” OR 1/4” NPT
  • Housing: Flame-Proof construction with 1/2″ NPT conduit
  • Listings: Valves are cULus listed for Hazardous Locations. — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2 Groups A, B, C, D, E, F, and G.
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: 1.38 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering, Manual Override, Alternate Elastomers*

Additional information

Weight1.5 kg
Type

Orifice/Port Size

1/8" or 1/4" NPT

Pressure

0 – 500 PSI

Flow

.024 – .284 CV

Wattage

1.8W

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G