Peter Paul Hazardous Location Valve Model E53

Contact us to get your personalized offer

PeterPaul single orifice valves have an orifice that remains closed in the de-energized position, preventing any flow between the inlet and outlet ports. Additionally, PeterPaul explosion-proof valves are essential in environments with fire or explosion hazards due to the presence of flammable gases, vapors, liquids, combustible dust, or easily ignitable fibers. These hazardous location valves are recommended, and sometimes compulsory, where a high level of explosion protection is necessary.

  • Miniature Hazardous Location valve.
  • Flame-Proof construction.
  • High quality engineering.

Available on backorder

Description

+ MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
ACDCINLETEXHINLETEXH
2002001/321/32.022.020E53GG8DCCM-∆
1501503/643/64.055.048E53HH8DCCM-∆
1501503/641/16.055.075E53HJ8DCCM-∆
1001001/161/16.075.075E53JJ8DCCM-∆
60603/321/16.156.075E53KJ8DCCM-∆
50503/323/32.156.156E53KK8DCCM-∆
30301/81/16.230.075E53NJ8DCCM-∆
30301/83/32.230.156E53NK8DCCM-∆

 

Ordering Information:

Seal Material:  Replace ∆ with desired code  –  Blank = Nitrile (Buna)      S = Low Temp Buna.      N = FKM*      E = Neoprene    A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (E53HJ8DCCM 120/60) repair pack (5KE53HJD AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE53HJDDCCM 120/60)

 

Operating Conditions:

  • Media: Air, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
  • Valve Temperature Range:
    • Standard Valves –0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
    • Optional Valves – can tolerate much higher or much lower ambient and media temperatures.
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 5000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics:

  • Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
  • Nominal Power: AC — 5.6 Watts DC — 7.2 Watts
  • Coil Construction: Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
  • Typical Response Time on Air: 4 – 16 Milliseconds
  • Operating Speed: Up to 600 CPM
  • Duty Cycle:  Continuous

 

Mechanical Characteristics

  • Body: Stainless Steel (Std.)
  • Internal Components: Stainless Steel. Copper – AC Only.
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Orifice Diameter: See table above.
  • Porting: 1/8″ NPT (Std.)
  • Housing: Flame-Proof construction with 1/2″ NPT conduit
  • Listings: Valves are cULus listed for Hazardous Locations. — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2 Groups A, B, C, D, E, F, and G.
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: 0.40 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering, Alternate Elastomers, All Stainless Steel Construction*

* Consult us for options and specifications

Additional information

Weight1.5 kg
Type

Orifice/Port Size

1/8" NPT

Pressure

0 – 200 PSI

Flow

.022 – .230 CV

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G