Peter Paul Hazardous Location Valve Model E25
PeterPaul dual orifice valves feature a closed body orifice and an open sleeve orifice in the de-energized position, preventing flow between the inlet and normally closed ports while allowing flow between the inlet and normally open ports.
Additionally, PeterPaul explosion-proof valves are essential in environments with fire or explosion hazards caused by flammable gases, vapors, liquids, combustible dust, or easily ignitable fibers. These hazardous location valves are recommended, and sometimes compulsory, where a high level of explosion protection is required.
- Explosion Proof
- The flagship valve initially created for fluid power industry.
- Heavy duty and made of stainless steel.
- A real workhorse with proven performance.
- It has the greatest amount of options available of all the valves.
- Wide range of orifice sizes from 1/32″ to 1/8″.
Available on backorder
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER | ||||
|---|---|---|---|---|---|---|---|
| AC | DC | N.C. | N.O. | N.C. | N.O. | 1/8 NPT PORTS | 1/4 NPT PORTS |
| 500 | 500 | 1/32 | 1/32 | .024 | .024 | E25GG7XCCM-∆ | E25GG9ZCCM-∆ |
| 235 (400) | 235 (300) | 3/64 | 3/64 | .052 | .052 | E25HH7XCCM-∆ | E25HH9ZCCM-∆ |
| 200 (225) | 200 (200) | 1/16 | 3/64 | .095 | .052 | E25JH7XCCM-∆ | E25JH9ZCCM-∆ |
| 150 (225) | 150 (200) | 1/16 | 1/16 | .095 | .095 | E25JJ7XCCM-∆ | E25JJ9ZCCM-∆ |
| 100 (150) | 100 (125) | 3/32 | 3/32 | .156 | .156 | E25KK7XCCM-∆ | E25KK9ZCCM-∆ |
| 100 (125) | 100 | 1/8 | 3/32 | .284 | .156 | E25NK7XCCM-∆ | E25NK9ZCCM-∆ |
| 35 (40) | 35 (40) | 1/8 | 1/8 | .284 | .227 | E25NN7XCCM-∆ ^ | E25NN9ZCCM-∆ ^ |
Ordering Information:
Seal Material: Replace ∆ with desired code – Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (E25NK9ZCCM 120/60) repair pack (2KE25NK AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE25NKDDCCM 120/60)
Operating Conditions:
- Media: Air, water, and other fluids compatible with standard Buna seals. Hot water, steam gasoline, and many oils require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
- Valve Temperature Range:
- Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
- Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
- Maximum Operating Pressure Differentials: See table above.
- Burst Pressure: 5,000 PSI
- Leakage: Bubble tight for standard valves.
- Vacuum: To 5 Microns*
Electrical Characteristics:
- Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
- Nominal Power: AC — 7.3 Watts DC — 9.5 Watts
- Coil Construction: Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
- Typical Response Time on Air: 4 – 16 Milliseconds
- Operating Speed: Up to 600 CPM
- Duty Cycle: Continuous
Mechanical Characteristics
- Body: Stainless Steel (Std.)
- Internal Components: Stainless Steel. Copper – AC Only.
- Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
- Orifice Diameter: See table above.
- Porting: 1/8″ and 1/4″ NPT (other ports available).
- Housing: Flame-Proof construction with 1/2″ NPT conduit
- Listings: Valves are UL listed for use in the United States and Canada for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2, Groups A, B, C, D, E, F, and G.
- Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
- Valve Weight: 1.50 lbs
- Repair Packs: See table above.
- Options: Alternate Port Locations, Metering, Alternate Elastomers, All Stainless Steel Construction*
* Consult us for options and specifications
| Weight | 1.5 kg |
|---|---|
| Orifice/Port Size | 1/8" or 1/4" NPT |
| Pressure | 0 – 500 PSI |
| Flow | .024 – .284 CV |
| SPECIAL NOTE | Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G |