Peter Paul Hazardous Location Valve Model E24

PeterPaul dual orifice valves feature a closed body orifice and an open sleeve orifice in the de-energized position, preventing flow between the exhaust and cylinder ports while allowing flow between the inlet and cylinder ports.

Additionally, PeterPaul explosion-proof valves are essential in environments with fire or explosion hazards caused by flammable gases, vapors, liquids, combustible dust, or easily ignitable fibers. These hazardous location valves are recommended, and sometimes compulsory, where a high level of explosion protection is required.

  • Explosion Proof
  • The flagship valve initially created for fluid power industry.
  • Heavy duty and made of stainless steel.
  • A real workhorse with proven performance.
  • It has the greatest amount of options available of all the valves.
  • Wide range of orifice sizes from 1/32″ to 1/8″.

Available on backorder

MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBERVALVE NUMBER
ACDCINLETEXHINLETEXH1/8 NPT PORTS1/4 NPT PORTS
4004001/321/32.024.024E24GG7XCCM-∆E24GG9ZCCM-∆
150 (225)1503/641/16.052.095E24HJ7XCCM-∆E24HJ9ZCCM-∆
100 (150)1001/161/16.095.095E24JJ7XCCM-∆E24JJ9ZCCM-∆
100 (125)1001/161/8.095.284E24JN7XCCM-∆E24JN9ZCCM-∆
75 (90)753/321/8.156.284E24KN7XCCM-∆E24KN9ZCCM-∆
30301/81/8.227.284E24NN7XCCM -∆^E24NN9ZCCM-∆ ^

^ VALVES WITH 1/8 ORIFICE ARE NOT UL OR CSA LISTED
+ Ratings in brackets are optional extended ratings; consult factory

Ordering Information:

Seal Material:  Replace ∆ with desired code  –  Blank = Nitrile (Buna)      S = Low Temp Buna.      N = FKM*      E = Neoprene    A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (E24K9ZCCM 120/60) repair pack (2KE24K AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE24KDDCCM 120/60)

 

Operating Conditions:

  • Media: Air, water, and other fluids compatible with standard Buna seals. Hot water, steam gasoline, and many oils require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
  • Valve Temperature Range:
    • Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
    • Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
  • Maximum Operating Pressure Differentials: See table above.
  • Burst Pressure: 5,000 PSI
  • Leakage: Bubble tight for standard valves.
  • Vacuum: To 5 Microns*

 

Electrical Characteristics:

  • Coil Voltage: 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
  • Nominal Power: AC — 7.3 Watts DC — 9.5 Watts
  • Coil Construction: Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
  • Typical Response Time on Air:  4 – 16 Milliseconds
  • Operating Speed:  Up to 600 CPM
  • Duty Cycle:  Continuous

 

Mechanical Characteristics

  • Body: Stainless Steel (Std.)
  • Internal Components: Stainless Steel. Copper – AC Only.
  • Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
  • Orifice Diameter: See table above.
  • Porting: 1/8″ and 1/4″ NPT (other ports available).
  • Housing: Flame-Proof construction with 1/2″ NPT conduit
  • Listings: Valves are UL listed for use in the United States and Canada for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2, Groups A, B, C, D, E, F, and G.
  • Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
  • Valve Weight: 1.50 lbs
  • Repair Packs: See table above.
  • Options: Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*

* Consult us for options and specifications

Weight1.5 kg
Orifice/Port Size

1/8" or 1/4" NPT

Pressure

0 – 400 PSI

Flow

.024 – .227 CV

SPECIAL NOTE

Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G