Hotstart CSM Series HOTflow Heating System for 75-100L Engines CSM11204-000
€1,977.53 (excl. VAT)
HOTSTART’s CSM HOTflow® heating system is a coolant preheater, developed to maintain optimal temperatures for diesel and gas engines in stationary land power, marine, construction equipment, and truck applications.
- This item has a 16 week lead time.
Available on backorder
Description
The CSM is a heavy-duty efficiency heating system that boasts the most powerful pump (10 gpm flow) and most powerful heating element options (up to 12 kW) in the HOTflow lineup. This energy-efficient system is designed to replace costly convection-based heaters in large-engine installations up to 100 L displacement.
The CSM’s control box allows for easy power connections and enables automatic heater operation, eliminating the need for additional customer-supplied control components.
The CSM lineup is equipped to meet a wide range of conditions, including power source requirements and agency certifications. This ensures that there is a CSM to meet your specific heating system application needs.
The CSM’s power and pump-driven forced circulation provides superior heat distribution, making it a viable option to replace paired or multiple convection-based heaters. This not only improves heating performance but also reduces maintenance costs, making it a cost-effective single heater solution.
Applications — Generator, Heavy equipment, Truck & Bus, Marine
Heating System Style & Dimensions — See product images
System Specifications
-Phase: Single-phase/Three-phase
-Voltage (60 Hz): 120V/208V/240V/440V/480V/575V
-Voltage (50 Hz): 230V/400V
-Control Box Ingress: NEMA 4/IP66
-Motor Ingress: NEMA 2 (UL-listed)/IP44 (CE-compliant)
-Min./Max. Ambient Temp: -4–104°F (-20–40°C)
-Certification: UL/C-US listed models available (E250789)
CE-compliant models available
Coolant Specifications
-Fluid Type: Water / Coolant mix (50% water/50% glycol)
-Heat Power: 3 kW/6 kW/ 9 kW /10.5 kW /12 kW
-Temp. Control: Fixed, 100–120°F (38–49°C)
-Pump Power: 97 W (60 Hz)/70 W (50 Hz)
-Flow: 10 gpm @ 10 ft WC (37.9 L/min @ 3 m WC)
-Max. Pressure: 125 psi (860 kPa)
-Pressure Loss: 0.2 psi (1.5 kPa)
– Inlet/Outlet: 1” NPT
Options shown represent typical tested or certified configurations. Additional options or configurations may be available. For assistance with your heating system application, contact SESCO at info@sesco.nl or 31-10-4849833
Ordering Information
.tg {border-collapse:collapse;border-spacing:0;}
.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;
overflow:hidden;padding:10px 5px;word-break:normal;}
.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;
font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}
.tg .tg-soib{border-color:inherit;color:#242021;text-align:center;vertical-align:top}
.tg .tg-of7u{background-color:#b4b4b4;border-color:inherit;color:#242021;text-align:left;vertical-align:top}
.tg .tg-c3ow{border-color:inherit;text-align:center;vertical-align:top}
.tg .tg-f1lz{background-color:#b4b4b4;border-color:inherit;text-align:center;vertical-align:top}
.tg .tg-e9gf{border-color:inherit;color:#242021;text-align:left;vertical-align:top}
.tg .tg-7ykk{background-color:#b4b4b4;border-color:inherit;color:#242021;text-align:center;vertical-align:top}
@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}
Engine Displacement | Power Supply | Heating System | |||||
---|---|---|---|---|---|---|---|
V | Phase | Hz | kW | Amps | Style | Model number | |
1000–2000 CID 15–25 L | 120 | 1 | 60 | 3 | 26.3 | A | CSM10301-000 |
208 | 1 | 60 | 3 | 15.1 | A | CSM10308-000 | |
208 | 3 | 60 | 3 | 8.7 | B | CSM30308-000 | |
230 | 1 | 50 | 3 | 13.7 | A | **CSM1030J-5A0 | |
240 | 1 | 60 | 3 | 13.1 | A | CSM10302-000 | |
400 | 3 | 50 | 3 | 4.9 | B | **CSM3030A-5A0 | |
480 | 1 | 60 | 3 | 3.8 | B | CSM10304-000 | |
480 | 3 | 60 | 3 | 4.4 | B | CSM30304-000 | |
2000–3000 CID 25–50 L | 208 | 1 | 60 | 6 | 29.6 | A | CSM10608-000 |
208 | 3 | 60 | 6 | 17.1 | B | CSM30608-000 | |
230 | 1 | 50 | 6 | 26.7 | A | **CSM1060J-5A0 | |
240 | 1 | 60 | 6 | 25.6 | A | CSM10602-000 | |
400 | 3 | 50 | 6 | 8.9 | B | **CSM3060A-5A0 | |
440 | 3 | 60 | 6 | 8.1 | B | **CSM3060F-5A1 | |
480 | 1 | 60 | 6 | 12.8 | B | CSM10604-000 | |
480 | 3 | 60 | 6 | 7.4 | B | CSM30604-000 | |
575 | 3 | 60 | 6 | 6.2 | B | CSM30605-000 | |
3000–4500 CID 50–75 L | 208 | 1 | 60 | 9 | 44.0 | A | CSM10908-000 |
208 | 3 | 60 | 9 | 25.4 | B | CSM30908-000 | |
230 | 1 | 50 | 9 | 39.8 | A | **CSM1090J-5A0 | |
240 | 1 | 60 | 9 | 38.1 | A | CSM10902-000 | |
400 | 3 | 50 | 9 | 13.2 | B | **CSM3090A-5A0 | |
440 | 3 | 60 | 9 | 12.2 | B | **CSM3090F-5A1 | |
480 | 1 | 60 | 9 | 19.1 | B | CSM10904-000 | |
480 | 3 | 60 | 9 | 11.0 | B | CSM30904-000 | |
575 | 3 | 60 | 9 | 9.2 | B | CSM30905-000 | |
4500–6000 CID 75–100 L | 208 | 1 | 60 | 10.5 | 51.2 | B | CSM11058-000 |
208 | 3 | 60 | 12 | 33.7 | B | CSM31208-000 | |
230 | 1 | 50 | 12 | 52.8 | B | **CSM1120J-5A0 | |
240 | 1 | 60 | 12 | 50.6 | B | CSM11202-000 | |
400 | 3 | 50 | 12 | 17.5 | B | **CSM3120A-5A0 | |
440 | 3 | 60 | 12 | 15.9 | B | **CSM3120F-5A2 | |
480 | 1 | 60 | 12 | 25.3 | B | CSM11204-000 | |
480 | 3 | 60 | 12 | 14.6 | B | CSM31204-000 | |
575 | 3 | 60 | 12 | 12.2 | B | CSM31205-000 |
** – CE-compliant/union pump configuration
Other voltages available. Consult us
Additional information
Weight | 26.5 kg |
---|---|
Type | |
Wattage | |
Voltage | |
Hertz Freq. | |
Phase |