Hotstart CLP Single Fluid Heating System

The HOTSTART CLP is a high-capacity coolant heating system designed to maintain optimal engine temperatures for diesel and gas engines in stationary land power and marine applications. This user-friendly, pre-packaged system includes all required components and features remote automation and customer interface connections for easy integration into existing control systems.

By circulating heated coolant throughout the engine block, the CLP ensures uniform temperature, prevents hot spots, and reduces the risk of overheating at shutdown. It improves startability, lowers NOx emissions at startup, and eliminates the need for extended idling—cutting maintenance costs.

In warm, humid environments, the CLP prevents condensation in the cylinders by maintaining temperatures above the dew point, reducing starting issues and wear.

Available on backorder

HEATING INFORMATION:
Primary Heating: Coolant Mix
Primary Heat Power: 11 kW, 12 kW, 17 kW, 18 kW, 24 kW, 30 kW, 33 kW, 36 kW

POWER SPECIFICATION:
Power Sources: AC, Single-Phase, 60 Hz; AC, Single-Phase, 50 Hz; AC, Three-Phase, 60 Hz; AC, Three-Phase, 50 Hz
Voltages: 230, 240, 380, 440, 400, 480, 600, 690

POWER CONNECTORS:
Hardwired

TEMPERATURE CONTROL:
Primary Temperature Control: 32–176°F (0–80°C), adjustable
Primary Temperature Control Set Points: 122°F (50°C), factory set
Primary High Limit Temperature: 195°F (90°C)

MOUNT TYPES:
Plate

INLETS/OUTLETS:
Inlets: 1” NPT
Outlets: 1” NPT

INGRESS OPTIONS:
Control Box Ingress: NEMA 4, IP66
Coolant Motor Ingress: IP55

CERTIFICATIONS:
CSA C/US, CE-compliant models available